Open Automatic Control System
CPBW FlexControl?
/ CPBW FlexControl /
Software
Pulse I/O
Equipment Parameters
Power Supply | 24VDC/24W |
Communication | Industrial Ethernet |
Communication Protocol | Modbus TCP/IP |
Output Pulse Voltage | 12/24VDC (Jumper Selection) |
Maximum Cycle No. of Pulse | 100K |
Number of Pulse Output Channels | 2 (Independent/Interpolated Output) |
Number of Pulse Input Channels | 2 (High Speed) |
Digital Input Channel | 8 (Low Speed) |
Digital Output Channel | 8 |
Storage Temp | -30~75℃ |
Working Temp | -30~55℃ |
Installation | DIN Rail Mounting |
Programing | Non Compiled/Object Function Block (can be deployed separately or integrated with FlexControl) |
Position Data | Can be continuous, discontinuous, intermittent with the form of temporary data package, predetermined data package or real-time data package. |